AC SOLID STATE RELAY IO-X-KB20_A Series (DC - AC)(1/2/4/8 Port)
AC SOLID STATE RELAY
IO-X-20C04A
COM (+)
COM (- )
IO-X-40C04A
COM (+)
COM (- )
(HEATEA LOAD ONLY)
IO SERIES
SPECIFICATIONS
MODEL
NO.
CONTROL
IMPEDANCE
MUST TURN
OFF VOLTAGE
INPUT
IMPEDANCE
MAX LOAD
CURRENT
LOAD VOLTAGE
RANGE
MIN BLOCKING
VOLTAGE
MAX OFF-STATE
LEAKAGE
FREQUENCY
RANGE
MAX 1-CYCLE
PEAK SURGE
CATALOG DOWNLOAD
IO-X-20C04A
4 TO 32 VDC
MAX 1.0 VDC
1.5 Kohm
4A
24-280VAC
280VAC
LESS 5 mA
47-70Hz
50A
IO-X-40C04A
4 TO 32 VDC
MAX 1.0 VDC
1.5 Kohm
4A
48-480VAC
280VAC
LESS 5 mA
47~63Hz
50A
MODEL
NO.
MAX OFF
STATE dv/dt
MAX ON-STATE
VOLTAGE DROP
ISOLATE
IMPEDENCE
DIELECTRIC STRENGTH
INPUT-OUTPUT
DIELECTRIC STRENGTH
INPUT,OUTPUT-CASE
TURN ON
TIME
TURN OFF
TIME
CAPACITANCE
IN-OUT
WEIGHT (g)
IO-X-20C04A
100 SEC
1.5VAC
ohm
4000 VACrms
_______
LESS 2 m See
LESS1/2cycle
LESS 15 PF
12 g
IO-X-40C04A
500 SEC
1.5VAC
ohm
4000 VACrms
_______
LESS 2 m See
LESS1/2cycle
LESS 15 PF
12 g
PS: X= 1PORT / 2PORT / 4PORT / 8PORT
OUTLINE DIMENSIONS(unit:mm)
Model
Dimension
(LxWxH)mm
IO-2-20C04A
IO-2-40C04A
34x85x51
IO-4-20C04A
IO-4-40C04A
64x85x51
IO-8-20C04A
IO-8-40C04A
124x85x51
EQUIVALENT CIRCUIT
CHARACTERISTIC CURVES
Attention:
In order to be in compliance with the EMC
Directive an additional X2 capacitor at the output is requried if the SSR is operated as single component. In case the SSR is incorporated in an appliance the existing
EMI filter may provide the required EMI
suppresion. The X2 capacitor must be
placed as close as possible to the output
temminats. See also above.
Kytech Electronics Ltd.
Kytech (Shenzhen) Electronics Ltd.
No.68, Ln. 131, Sec. 4, Fudan Rd., Pingzhen City, Taoyuan County 324, Taiwan (R.O.C.)